I N S T R U C T I O N M A N U A L
Flashing
Set start hours
SEL
SEL
Set the stop minutes
SEL
SEL
Informs that it is
stop time
Set the stop hours
SEL
SEL
Now select the days of the week.With the Select button, run through
the various days, using the OK button to change the day's status from
deactivated to activated or vice-versa; the day then moves forward
one day.
Flashing
Active Monday
OK
Skip Tuesday and
move to Wednesday
SEL
Skip Thursday and Friday
SEL
SEL
When Sunday is passed, the selected days flash. If any alteration
is desired, press Select; if you wish to validate the set days, press
OK.
Skip Sunday
Confirm the
select days
SEL
OK
At this point programme no. 2 can be entered, or programming
exited by leaving the buttons unpressed for 10 seconds.
If there are overlapping programmes, the last one activated has
the highest priority. Example: two programmes that activate on the
same day as follows.
12:00
P1
P2
BOMBA
Confirm hours
Flashing
Flashing
Confirm hours
Confirmar
Mo Tu
Flashing
Wednesday
Mo
We
and move to
Thyrsday
Confirm Saturday
and move to
Mo
We
Sa Su
Sunday
OK
Flashing
12:30
12:45 13:00
3.6 - Deactivating a programme
To deactivate an automatic programme all the days of the week of
the programme in question have to be deactivated.
OK
3.7 - Lack-of-water protection
The lack-of-water safety programme remains in operation whene-
ver the pump is running. If the circuit detects that the pump has
Confirm
been running without any water for more than 10 seconds, the
the minutes
alarm is activated and the pump stops.
OK
Pump stopped
OK
Should a voltage transient appear in the line while the pump is in
operation, the alarm will be activated and the pump will stop. It will
restart after 15 minutes.
3.8 - Unblocking the fault condition
To exit from the fault condition, press OK for more than 2
las horas
seconds. If the appliance is in automatic mode and the stop time
arrives, the fault condition disappears.
OK
In fault condition the circuit will try to start up again after 15 minu-
tes; if it is not successful, further attempts will be made at 30
Confirm
minutes, 45 minutes and 1 hour after the previous attempt. After
this, no further attempts will be made.
OK
4. Starting
Ensure all valves in the pipework are open.
Connect power supply. There will be a delay before water appears at the
end of the discharge pipe.
If the pump fails to operate refer to the possible faults, causes and solu-
tions list for assistance.
For the pump to work correctly, it is essential that the filter unit
(recirculating pump) is also running.
5. Maintenance
Under normal conditions these pumps require no special or
planned maintenance.
If the pump is not to be operated for a long period it is recom-
mended to remove it from the installation, drain down and store
in a dry, well ventilated place.
ATTENTION: In the event of faults or damage occurring to the
pump, repairs should only be carried out by an authorised ser-
vice agent.When the pump is eventually disposed of, please
note that it contains no toxic or polluting material. All main com-
ponents are material identified to allow selective disposal.
7
GB
Alarm activated,
segment flashing