nect the safety measuring lines from the measuring point.
-
Strong sources of interference in the vicinity of the BENNING CM 1-3 might
involve unstable readings and measuring errors.
8.2 Voltage measurements
Do not exceed the maximum permitted voltage with respect to
earth potential! Electrical danger!
The highest voltage that may be applied to the jacks
-
COM jack 6
-
jack for V and Ω 7
of the BENNING CM 1-3 against ground is 1000 V.
-
Select the desired function (V AC) or (V DC) by means of the rotary switch
2 of the BENNING CM 1-3.
-
Connect the black safety measuring line to the COM jack 6 of the
BENNING CM 1-3.
-
Connect the red safety measuring line to the jack for V and Ω 7 of the
BENNING CM 1-3.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display 3 of the
BENNING CM 1-3.
See figure 2:
See figure 3:
8.3 Current measurements
8.3.1
Preparing the measurement
Operate and store the BENNING CM 1-3 at the specified storage and operating
temperatures only! Do not permanently expose the device to sunlight.
-
Strong sources of interference in the vicinity of the BENNING CM 1-3 might
involve unstable readings and measuring errors.
Do not apply any voltage to the output contacts of the
BENNING CM 1-3! Any possibly connected safety measuring
lines have to be removed.
8.3.2
Current measurements
-
Select the desired function (A~) by means of the rotary switch 2 of the
BENNING CM 1-3.
-
Push the fork over the conductor wire. The conductor wire must be in the
open area.
-
Read the value indicated on the digital display 3.
See figure 4:
8.4 Resistance measurements
-
Select the function (Ω) by means of the rotary switch 2 of the
BENNING CM 1-3.
-
Connect the black safety measuring line to the COM jack 6 of the
BENNING CM 1-3.
-
Connect the red safety measuring line to the jack for V and Ω 7 of the
BENNING CM 1-3.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display 3 of the
BENNING CM 1-3.
Note:
-
To obtain a correct measurement, ensure that no voltage is applied to the
measuring point.
-
With small resistances, the measuring result can be improved by measuring
the resistance of the safety measuring wires beforehand by short-circuiting
the measuring tips and subtracting the reading obtained from the resistance
measured.
See figure 5:
8.5 Diode tests
-
Select the function (
BENNING CM 1-3 and press the HOLD
-
Connect the black safety measuring line to the COM jack 6 of the
BENNING CM 1-3.
-
Connect the red safety measuring line to the jack for V, Ω 7 of the
BENNING CM 1-3.
05/ 2008
DC voltage measurement
AC voltage measurement
AC current measurement
Resistance measurement
) by means of the rotary switch 2 of the
BENNING CM 1-3
-key „diode test".
13