Technical Data - Ritos 6095115AIP20 Indicación Para El Montaje Y El Servicio

Reflector de halógeno con soporte
Tabla de contenido

Publicidad

GB
Halogen floodlight with stand
Operation and maintenance manual
Dear valued customer,
Thank you for purchasing our floodlight.
Before operating the floodlight, please read the following instructions for use carefully and keep
them in a safe place for future reference.
Proper Use
Type
6095115AIP20,
6096150AIP20:
The IP20 designated floodlights are only suitable for use in a dry interior. Not suitable for heavy duty
work.
Type
6095115AIP44,
Typ 6096150AIP44:
The floodlight is spray-protected, IP44 and for use outdoors.
The floodlight conforms with the appropriate European CE regulations.
General Safety Instructions
• must always be placed at least 1m away from the surface being illuminated – in particular, the
power cable must not be illuminated or come into contact with the metal housing – maintain the
specified minimum clearances.
• must always be given sufficient time to cool down – the floodlight housing can get extremely hot –
the power supply to the floodlight must always be disconnected and locked out before servicing,
e.g. for bulb replacement or cleaning.
• must only be used on flat, stable surfaces.
• use only with a sufficiently protected 230V~ installation.
• must not be used in rooms that represent an explosion hazard (e.g. cabinetmaker's workshop,
painting operation, or similar).
• must not be used in the immediate vicinity of flammable materials.
• must not be set up in the immediate vicinity of pools, fountains, ponds, or similar bodies of water.
must not be immersed in water or other liquids.
• must not be immersed in water or other liquids.
• must not be operated with wet hands; never look directly into the light source.
• must never be covered.
• must never be operated with an open housing, missing or damaged wiring compartment, or
missing or damaged lens.
• must never be sprayed or cleaned using a steam pressure cleaner since this can damage the
insulation and seals.
• must never be repaired by the user. Repairs must only be carried out by the manufacturer or an
authorized service representative.

Technical Data

• Type 6095115AIP20: Output: max. 150W
• Type 6096150AIP20: Output: max. 500W
• Type 6095115AIP44: Output: max. 150W
• Type 6096150AIP44: Output: max. 500W
• Voltage: 230V~, 50Hz
6
Protection class: IP20
cable: H05VV-F
Protection class: IP20
cable: H05VV-F
Protection class: IP44
cable: H05RN-F
Protection class: IP44
cable: H05RN-F
Illuminant Installation
• Loosen the screw on the top of the floodlight and swing the lens forward.
• Remove the illuminant from the packaging.
• Avoid touching it with bare hands since this causes grease stains which lead to overheating. Use
a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end of the
illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
Installing the Handle and Base
Loosen the wing nut on the support and insert the base into the handle. Insert the wing nut into the
hole provided on the handle and tighten it.
Setting the Floodlight Direction
Loosen the screws on the sides of the mounting brackets, adjust the floodlight direction, and then
retighten all screws.
Replacing the Illuminant
You can find the technical data for the illuminant under "Technical Date" or on the type plate
attached to the floodlight housing.
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool down
sufficiently!
• Loosen the screw for the lens on top of the floodlight and swing the lens forward.
• Remove the illuminant from the packaging.
• Avoid touching it with bare hands since this causes grease stains which lead to overheating. Use
a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end of the
illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
Cleaning
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool down
sufficiently!
• Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent if required. Do not
use cleaners that contain abrasives or solvents.
• If required, the illuminant can be cleaned with a lint-free cloth moistened with ethyl alcohol.
ATTENTION! After cleaning the illuminant with ethyl alcohol, it must be allowed to air dry for at
least 20 minutes.
Maintenance
• If the lens is damaged it must be replaced immediately.
• Clean any dirt from the housing or the lens immediately, since it could cause overheating.
GB