D3
L13
L14
L15
Immediately after it shows the values preset by the weld-
ing machine manufacturer:
The lower portion of the display shows (MEM, PAR, 2T/4T
and JOB) that can be selected by means of the function
keys T6, T7, T8, T9 (see par. 8).
6.3 ALARM DISPLAY
When the machine detects a temporary alarm, displays
D1 and D2 show a fl ashing wording related to the alarm
cause. FOR example: if the wire feeder door is opened,
the wording "OPn"
6.4 ERROR DISPLAY
When the machine detects a serious alarm, displays D1
and D2 show a wording "Err" followed by the relevant
error code.
In this case, switch off the machine and contact technical
.
service (see par. 10)
T5
T6
T7
- Date (day/month/year)
and time (hour and min
utes).
- Synergic MIG Process .
(Led L10 on).
- Welding wire type SG2 ø
1.0 mm.
- Gas Ar/18% CO2.
- 2 stages Start-up mode
2T.
T8
T9
L10 L11 L12
7 MACHINE PROGRAMMING
"Main Menu" -
L13
L14
L15
T5
T6
Programming is made in the "Main Menu" . To access,
press key T5 and then key T6 (MENU) or through the
quick access menu described under paragraph 8.
In the " Main Menu ", via keys T10 and T11, it is possible
to select one of the list items highlighted by the yellow
band. With key T12 enter the submenu, while with key
T13 return to the previous menu and save, at the same
time, the selection made.
A downward arrow indicates that there are additional
items not shown on the screen.
This surfi ng mode applies to all machine menus.
The available items in the "main menu " are:
- "Process Parameters" (See par. 7.1)
- "Jobs" (See par. 7.2)
- "Settings" - (See par. 7.3)
- "Information" (See par. 7.4)
T13
T8
T7
T9
L10 L11 L12
T13
T10
T12
T11
Fig. 14
T10
T12
T11
27