CEBORA S.p.A.
Power Source MIG 3540/TS,
art. 315.80 : 350 A. multi-voltage.
Power Source MIG 3840/TS,
art. 316.80 : 380 A. single-voltage.
Power Source MIG 5240/TS,
art. 317.80 : 520 A. single-voltage.
3
INSTALLATION.
This equipment must be used solely for welding
operations.
The equipment must be installed by qualified
personnel.
All connections must be carried out in
compliance with current standards and in full
observance of current safety laws.
3.1
Placement.
The combined weight of the Power Source and
Cooling Unit is approximately 100 Kg, thus
when lifting following the instructions shown in
fig. 3.
fig. 3
Position the Power Source in an area that ensures
good stability, and efficient ventilation so as to
prevent metal dust from entering.
3.2
Power Source installation (fig. 2).
If present, place the Robot Interface (25) inside
the Robot Control cabinet (5), following the
instructions provided in the Robot Interface
Instruction Manual.
with Robot Interface connect the Power
Source (21) to the Robot Interface (25) using
the signal cable (3) and the CANopen cable
(4) (the latter is included in the Robot
Interface);
3.300.354
without Robot Interface connect the Power
Source (21) directly to Robot Control using
the signals cable (3) and the CANopen (4)
cable (the latter must be requested separately
to Cebora).
Connect the Power Source (21) to the Control
Panel (24) using the connection cable (1).
Connect the Power Source (21) to the Wire
Feeder (8) by means of the extension (2).
NOTE: avoid coiling the connection to reduce to
a minimum the inductive effects that
could affect the results in pulsed
MIG/MAG welding.
Mount the plug on the power cord, being
especially carefully to connect the yellow/green
conductor to the earth pole.
Make sure that the supply voltage corresponds to
the rated voltage of the Power Source.
Size the protective fuses based on the data listed
on the technical specifications plate of the Power
Source.
Complete the remaining connections of the other
welding system equipment, consulting the
relevant
Instruction
"Installation".
Power up the Welding System using the switch
M of the Power Source (fig. 4).
NOTE: The Cooling Unit is preset by the factory
to OFF. Change this setting if a water-
cooled torch is used (see par. 5.4).
3.3
Setting up the Cooling Unit (fig 4).
Unscrew the cap T and fill the 5-liter tank.
The device is supplied by the factory with
approximately one litre of fluid already present.
It is important to periodically check, through the
slot S, that the fluid remains at the "max" level.
As a coolant, use water (preferably de-ionized)
mixed with alcohol, in the percentage shown in
the following table:
Temperature
0°C up to -5°C
-5°C up to -10°C
15
Manuals
in
par.
water/alcohol.
4L/1L