NOTE: If the pump turns with no coolant
present, you must remove all air from the
tubes:
- shut off the Power Source and fill the
tank;
- disconnect the blue tube of the Power
Source - Wire Feeder extension (2)
from the fitting Z;
4
POWER SOURCE.
GB
4.1
Overview.
The Power Source does not work independently,
but must be connected to the other system
equipments. The Power Source is the main power
supply of the Welding System and provides the
3.300.354
- connect one end of a new tube to the
free fitting Z and insert the other end
of the pipe in the tank;
- run the Power Source and then the
Cooling Unit for approximately 10/15
seconds to fill the pump;
- shut off the Power Source and reset
the tube connections of the Power
Source - Wire Feeder extension (2).
fig. 4
supply voltages to all other equipments.
The equipments may be used only for the
purposes described in the present manual.