Condominium function for partial open command (from remote control)
Overhead door open indicator / photocell test function
The indicator is off when the door is closed, and steadily lit during manoeuvres and when the door is
open.
If the door is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC
Setting deceleration during opening
Setting deceleration during closing
switch.
Setting door closed position
The value set must ensure that the door is closed correctly after the limit switch is activated.
Warning!
Motor revolutions.
Setting pressure against door closed stop
N.B.: as the door approaches the door closed stop, once the limit switch is activated, the control unit
reduces the torque applied by the motor to prevent the structure of the overhead door from bending
or straining.
Warning! This parameter must be set in relation to the type of door installed and the mounting used
for the gear motor.
Partial opening adjustment (%)
N.B.
).
From 10% to 85% of total door travel.
Setting automatic closing time
The timer starts from the door open state and continues for the set time. Once the set time is reached,
the door closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection
system.
From 0 to 30 s.
Enable electric lock
Disabled.
manoeuvre.
lock.
43