Electrical data
Time until ready for operation after switch on < 1.5 s
Switching capacity of signal outputs
Safety classification
Directives
Standards
Test principle
Safety functions
Vibration resistance (DIN EN 60068-2-6)
Shock resistance (DIN EN 60068-2-27)
Safety classification
Service life
Common Cause Failure – CCF
Diagnostic coverage (DC)
Maximum Cycle Rate
Monitoring
Noise level [dB (A)]
Minimum Operation Frequency
Further technical data can be found in our online catalog at
www.aventics.com/pneumatics-catalog
AVENTICS™ AS3-SV | R412026750-BAL-001-AE | English
41–42: 24 V DC, 0.2 A
2006/42/EC (Machinery Directive)
2004/108/EC (EMC directive)
ISO 13849-1, IEC61508/IEC62061,
DIN EN 61326-3-1
GS-IFA-M07, April 2017
"Safe exhaust" and "protection against unex-
pected start-up"
0.35 mm ± 0.05 mm displacement at 10 Hz–
55 Hz
30 g with 18 ms duration
Shock wave form: Sinus half-wave
Max. category 4, PL e, SIL 3
See B
from the AVENTICS SISTEMA library
10D
> 65
High, 99%
2/s, measured without volume
The switching frequency reduces depending
on the volumes to be filled.
Dynamic, cyclic, internal
Monitoring of the control state of sensors
with all state changes of valve control signals.
The sound pressure level is influenced by the
individual systems to reduce noise emissions.
Exhausting of the valve may not be re-
stricted. We do not recommend using the
product without silencers.
Once per month to guarantee perfect work-
ing order.
27