will.continue.for.15.minutes.
From. that. moment,. the. boiler. will. start.
working. in. heating. mode. at. maximum.
power,.with.cut.off.at.80°C.and.re-ignition.
at. 70°C. (ATTENTION!  Temperature  may 
reach excessive values when using unpro-
tected  low  temperature  plants.  Before 
activating  the  chimney  sweep  function 
make  sure  that  the  radiator  valves  or 
eventual zone valves are open)..
The. test. can. also. be. carried. out. with. the.
boiler.working.in.D.H.W..mode..
For. this,. after. activating. the. chimney.
sweep. function,. open. one. or. more. hot.
water.faucets..
Under.these.conditions,.the.boiler.will.fun-
5
5
ction. at. maximum. power. with. the. D.H.W..
circuit.kept.at.between.60°C.and.50°C..
During.the.test,.the.hot.water.faucets.must.
remain.open.
3
3
If. the.
key.
. and.
.
are. pressed. during.
the.15.minutes.of.the.chimney.sweep.fun-
1
1
ction,. the. boiler. will. be. brought. respecti-
vely.to.maximum.and.minimum.power.
5
The chimney sweep function will automa-
2
2
tically switch off after 15 minutes or when 
3
is pressed again.
the key .
.
4
4
1
4.5.2 
Operation floor drying
(fig. 22)
2
The. operation. floor. drying. keeps. the. floor.
at. a. pre-established. temperature. profile.
and. it. is. activated only for those systems 
4
combined  with  the  mixed  zone  card 
ZONA MIX code 8092275/76..
The. temperature. profiles. can. be. selected.
by. means. of. the. installer. parameter. PAR.
43:.
0.=.Not.activated.function
1.=.Curve.setting.A
2.=.Curve.setting.B
3.=.Curve.setting.A.+.B
The. turning. off. of. . the. function. happens.
clicking. on. the. button. OFF. (return. of. PAR.
43. to. the. value. 0). or. automatically. at. the.
end.of.the.function..
The.set.of.the.mixed.zone.follows.the.deve-
lopment.of.the.selected.curve.and.reaches.
a.maximum.of.55°C..
During. the. function. all. the. other. heating.
demands. are. ignored. (heating,. sanitary,.
antifreeze.and.chimney.sweep)..
During. the. functioning. the. display. shows.
the. remaining. days. for. the. completion. of.
the.function.(example.mains.digits.-15.=.15.
days.lack.to.the.end.of.the.function)..
The. diagram. fig.. 22. reports. the. deve-
lopment.of.the.curve.
ATTENTION:
-   Observe  the  relevant  standards  and 
regulations of the floor manufacturer!
-   Proper  functioning  is  ensured  only 
when  the  plant  is  correctly  installed 
(hydraulic  system,  electrical  installa-
tion, settings)! If not observed, the floor 
might get damaged!
[TVw]
55
50
45
40
35
30
25
20
0
1
5
7
1
X
A
1
TVw.
Flow.temperature.setpoint
Tag.
Period.in.days
x.
Start.day
A.
Functional.heating
B.
Floor.curing.heating
5
10
15
B
A + B
ES
PT
ENG
2
Fig..21
18
[Tag
]
25
Fig..22