Errors
"Tank empty" indicator
en
(4, Fig. 1) lights up in red
although water is still in
the tank.
Steam is discharged even
after the steam button
has been released.
Tank cap cannot be
opened.
POWER steamer 2:
When a unit is cold, the
manometer indicates vac-
uum pressure.
Calcium deposits in the
funnel-shaped upper
housing.
POWER steamer 2:
After switching on, the
pump runs several times
to fill the pressure tank.
Pulsating steam jet.
7.1
Flashing sequences
The indicators
• "Tank empty" indicator (red) (4)
• "Heating / Ready for operation" indicator (orange / green) (5)
• "Calcification state" indicator (yellow) (6)
show different operating and error states.
Color (indicator) Behavior
Red (4)
Red (4)
Orange (5)
Orange (5)
Green (5)
Green (5)
Green (5)
Yellow (6)
Red (4)
(*): Flashing is repeated for the specified number of times after approx. 3 seconds.
Additional flashing of the red LED indicates error states that the user cannot resolve.
Cause
• Calcium deposits have collected in the
pressure tank or too much sludge has
collected�
• The calcification indicator was ignored.
• The solenoid valve is jammed due to
particles of dirt�
• The pressure tank is still pressurized�
• The vapor pressure of the water at room
temperature is lower than that of air�
• Excess water was not removed after
filling.
• The inlet pressure is so low that the con-
tainer cannot be filled in the permitted
maximum pump run time�
• Simmering water is drawn into the
steam outlet opening because the pres-
sure tank has been filled to the maxi-
mum�
Meaning
On
Tank empty
Flashing
If the unit is switched off:
The temperature of the pressure tank is still above 80°C�
On
Heating / reheating
Flashing
Waiting for cooling with new water before reheating�
On
Working pressure reached�
Flashing slowly
Steam outlet function activated�
Flashing quickly
Rinsing in progress (POWER steamer 2 only)�
Flashing
Calcification limit reached.
Flashing 2x (*)
POWER steamer 2 only:
During operation, the mains water connection no longer has any water
pressure�
• Rinse / de-scale the pressure tank (see Chap. 6.3
and 6�4)�
• Remove the cover in the middle and tap the sole-
noid valve, for example using the handle of a screw-
driver�
• Do not force open the tank cap!
• Release all the pressure, e�g�, using the steam out-
let function (see Chap� 5�4), or if the tank is empty
(red indicator is on) by pressing the steam button�
• No action required�
• Switch on the unit and briefly press the steam but-
ton� Pressure compensation is achieved by opening
the solenoid valve�
• Wipe off calcium deposits.
• Always remove excess water after filling.
• No action required�
• This behavior resolves itself after working for a
short time�
• Only fill the unit with the recommended quantity of
water�
- 18 -
Corrective action
4
5
6
Fig.
19