MENU
SP INCR LOW TEMP
DECR COOLING SP
PUMP DUTY CYCLE
RESET CH TIMERS
DHW THERMOSTAT
SLIDING OUTLET
CH DELAY POST-DHW
CH DELAY TIME
PRESS TRANSDUCER
AUTO WATER FILL ENABLE
BEGIN SYSTEM FILLING
PREHEATING
DHW DELAY
DO_AUX1
CONFIG OTBUS
WEATHER COMPENSATION
CLIMATIC CURVES
FIXED SET POINT
NIGHT COMP
CURVE SLOPE
AMBIENT INFLUENCE
OFFSET
COOLING
COOLING CURVE
BUILDING TYPE
OUTDOOR REACTIVITY
ENABLE/DISABLE COOLING CURVE
RANGE RATED
CALIBRATION
MIN
MAX
RLA
MAX CH
COMBUSTION ANALYSIS
ACTIVATE FUNCTION
DEACTIVATE FUNCTION
MAX SPEED
RANGE RATED SPEED
MIN SPEED
CHANGE FAN SPEED
ANTI-LEGIO
ANTILEGIO FLOW
ANTILEGIO TIME
ANTILEGIO TEMP
DEFAULT VALUE FACTORY
MINIMUM
SET
0°C
0°C
85
FUNCTION NOT ACTIVE
FUNCTION NOT ACTIVE
ABSOLUTE
RELATED
DEACTIVATE FUNCTION
DEACTIVATE FUNCTION
0
6 sec
1
1
0.6
0
0 sec
0
1
MAIN
80.5 °C (HT)
MIN CH SET
45 °C (LT)
FUNCTION NOT ACTIVE
FUNCTION NOT ACTIVE
2.0
0.4
2.0
10
20°C
18°C
1
5 min
20
not used
see MULTIGAS TABLE
see MULTIGAS TABLE
see MULTIGAS TABLE
see MULTIGAS TABLE
MAX
RANGE RATED
MIN
CURRENT SPEED
FUNCTION NOT ACTIVE / DAILY FUNCTION / WEEKLY
WEEKLY FUNCTION
80°C
03:00
70°C
MAXIMUM
VALUE
VALUE
0°C
6°C
0°C
10°C
0
100
FUNCTION ACTIVE
ABSOLUTE
ACTIVATE FUNCTION
0
1
1 sec
255 sec
0
1
0
1
0.4
1
0
2
0 sec
60 sec
0
2
0
1
MAIN / ZONE 1 / ZONE 2
MAX CH SET
FUNCTION ACTIVE
1.0
3.0
0.2
0.8
1.0
5.0
0
20
20°C
40°C
4°C
20°C
1
2
5 min
20 min
0
255
MIN
MAX
FUNCTION
65°C
85°C
00:00
23:30
55°C
T MAX TANK
ENGLISH
EN
ACCESS LEVEL
SET
NOTES
VALUE
SERVICE
SERVICE
INSTALLER
INSTALLER
INSTALLER: only in
instantaneous confi guration
INSTALLER: only in "heating only"
confi g. and water tank with probe
SERVICE
SERVICE: if CH DELAY POST-
DHW = 1
SERVICE
SERVICE: only if PRESS
TRANSDUCER = 1
SERVICE: only if AUTO WATER
FILL ENABLE = 1
SERVICE: only in instant. confi g.
and managed by the control board
SERVICE: only in instant. confi g.
INSTALLER: only if control boards
with OT+
SERVICE: only if control boards
with OT+
INSTALLER
INSTALLER
INSTALLER: if EXTERNAL
PROBE NOT connected
INSTALLER: if EXTERNAL
PROBE connected
INSTALLER: if EXTERNAL
PROBE, request type TA and
zone type HT
INSTALLER: if EXTERNAL
PROBE, request type TA and
zone type LT
INSTALLER: if request type
AMBIENT PROBE or REC10CH
INSTALLER: if request type
AMBIENT PROBE or REC10CH
INSTALLER: if request type
AMBIENT PROBE or REC10CH
INSTALLER: if COOLING CURVE
deactivated
INSTALLER: if COOLING CURVE
activated
INSTALLER: if EXTERNAL
PROBE connected
INSTALLER: if EXTERNAL
PROBE connected
INSTALLER: if HP present and
enable to COOLING
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER
INSTALLER: only if "only heating"
confi g. and water tank with probe
INSTALLER
INSTALLER
INSTALLER
11