MOUNTING OPTIONS

If there is not an existing UL (cUL for Canadian Installation)
listed mounting box, then read the following instructions.
Disconnect the power by removing fuses or turning off circuit
breakers.
Secure the outlet box directly to the building structure. Use
appropriate fasteners and building materials. The outlet box
and its support must be able to fully support the full weight
of the fan (up to 15.9kg (35 pounds)). Do not use plastic outlet
boxes.
Figures 1, 2 and 3 are examples of different ways to mount the
outlet box.
NOTE: If you are installing the ceiling fan on a sloped (vaulted)
ceiling, you may need a longer downrod to maintain proper
clearance between the tip of the blade and the ceiling. A
minimum clearance of 12" is suggested for optimal operation.
NOTE: You must use 12" or longer downrod for 22° slope
(max angle 22°). (Fig. 3)
NOTE: Depending on the location you have selected for
installation, you may need to purchase and install a joist
hanger for the support of the outlet box. Make sure the joist
hanger you purchase has been designed for use with ceiling
fans. (Fig. 4)