Descargar Imprimir esta página

Optional Accessories - Aprimatic CONTROL NK Instrucciones Para La Instalación Electrica, El Uso Y El Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CONTROL UNIT
4.3

OPTIONAL ACCESSORIES

The following accessory devices which may be used
within the system are connected to the card with a quick-fi t
connector or using the removable terminal board K3 (13
screw-in pins).
The possible connections are illustrated in the diagram in Fig.7.
!
Warning
Always make the connections with the power OFF. Also
disconnect the emergency batteries, if present! If a device is
replaced or added after setting-up and starting the system, apply
a system RESET.
- EMERGENCY (PE pushbutton)
Connect an emergency pushbutton fi tted with an N.C.
type contact following the diagram in fi g.7.
WARNING: use a turn release maintained push-button.
If not used, the emergency contact must be jumpered as
it is an N.C. type contact.
Note: you can also apply this command using alarm systems
(fi re alarms, etc.) connected, following the instructions for such
devices installed.
-- STOP (door stop for mechanical emergency door opener)
Connect the STOP device fi tted with N.C. type contact
(SMI or SMS sensor or ER6/N photocell), following the
diagram in fi g.7 and the instructions provided with the
device itself.
If not used, the stop contact must be jumpered as it is an
N.C. type contact.
- ELECTRIC LOCK
Connect the electric lock to the NK CONTROL card
using the connector J9 (fi g.7), following the instructions
provided with the device.
- FIRST INPUT FUNCTION
Connect the SME/E or a similar pushbutton/device
with N.O. contact following the diagram in fi g.7 and the
instructions provided with the device installed.
Note: the fi rst input function is only active in Night lock mode.
- RADAR
Connect the RADARS following the diagram in fi g.7 and
the instructions provided with the devices installed.
RADAR 1 = ENTRANCE Radar.
RADAR 2 = EXIT Radar.
- PHOTOCELLS: ER4N OR ER6N TYPE
Connect the ER4N or ER6N type photocells following the
diagram in fi g.7 and the instructions provided with the
devices installed.
The photocell contact may be N.O. or N.C. depending on
the corresponding dipswitch setting (see Settings). If N.C.,
the contact must be jumpered when not used.
ER6N
Note: the
photocells consist of: transmitter, receiver and
separate amplifi er. The amplifi er card, usually housed in the
beam, must be connected to the unit as specifi ed in fi g.7.
4.4
MASTER/SLAVE (M/S) function
Connect the two automation units in Interlock mode following
the diagram in fi g.7.
IMPORTANT: you must enable M/S mode on both cards using the
corresponding dipswitches (see Settings).
CONTROL NK
- 20 -

Publicidad

loading