CONTROL UNIT
5.
START-UP
When you have completed and checked the electri-
cal connections, before powering the system, make the
DIPSWITCH SETTINGS for DP1 DIPSWITCH group as
described below.
5.1
Settings (DP1 DIP-SWITCH group)
Tab. 6 illustrates the possible settings using the DP1
DIPSWITCH group.
1 Partial opening - when traffi c is considerable, it is
established if the partial opening remains as set using the
trimmer P6 or is adapted (it increases automatically as the
traffi c increases and vice versa).
2 Break-in - if there is a break-in attempt, it is established
if the automation is free (the gear motor is not triggered) or
resistant (the motor prevents wing opening).
3 M/S - Master/Slave mode is enabled or disabled when
two automations are connected to each other.
4 Closing speed - adjusts the closing speed value as a
percentage of the opening speed (also see Trimmer P5).
5 Photocell - to set the type of contact used for the obstacle
detection photocells: NO or NC.
6 Continuation during power failure - if the mains power
fails, continuation of the mode set is enabled or disabled
(using the emergency batteries). If continuation is disabled,
when there is a power failure, the operation set using DIP7
is carried out immediately.
7 Last operation during power failure - if the mains power
fails, this establishes the operation for the automation to
perform using the emergency batteries: opening or closing.
The door stops in this position until the power returns.
Note: Dipswitches 6 and 7 are connected: if continuation is
enabled, the last operation is only carried out when the batteries
reach the critical voltage threshold; if not, the last operation is
carried out when the power fails.
Note: when the power returns, the automation starts to operate
again in the mode set previously.
8 Exit only electric lock - enables or disables the lock for
every closing operation when the automation is in automatic
EXIT ONLY mode.
9 Emergency - establishes the operation which the
automation performs if the emergency button is pressed:
opening or closing (the door stops in this position).
Note: when the PE emergency pushbutton is released, the
automation starts to operate again in the mode set previously.
10 N.L. mode power failure - establishes electric lock
maintained or OFF if there is a power failure when the door
is set to Night Lock mode.
11 N.L. mode stop - enables or disables the Stop with
mechanical emergency when the door is set to Night Lock mode.
12 not used.
DL1
DL2 (verde)
DL9 (visibile lato connettore J9) Lock inserted
Accessory devices connected to terminal board K3 (see Fig.7) :
EMR
RAD.1
RAD.2
FOTO
STOP
M/S
tab. 6 -
LED functions
Diagnostic and alarms
Mains power supply presence
EMERGENCY pushbutton
Entrance RADAR
Exit RADAR
Photocell
STOP pushbutton
Master/Slave mode
CONTROL NK
fig. 8 -
Trimm
er and LED
MERGENCY
18
RADAR 1
17
TEST PHOTOC.
16
RADAR 2
15
HOTOCELL
14
STOP
13
M/S IN
12
M/S OUT
11
M/S COM
10
RESET
ISP
SW1
JP3
RIT. BN
P1
DL9
tab. 4 -
DP1 Dip-Switch group Position 0 (OFF)
1 Partial opening fi xed
2 Break-in
free
3 Master-Slave
M/S enabled
4 Closing speed 75% opening
speed
5 Photocell
N.O.
6 Continuation
enabled
during power
failure
7 Last operation
closes
during power
failure
8 Electric lock
disabled
only for Exit
9 Emergency
closes
10 power failure in
releases the door maintains locked
N.L. mode
11 STOP input in
STOP disabled
N.L. mode
12 not active
tab. 5 -
DP1 DIP-SWITCH
1
OFF (fi xed partial opening)
2
OFF (door free after break-in attempt)
3
ON (M/S disabled ; 1st input enabled)
4
ON (closing speed = 100% of opening speed)
5
ON (photocell contact = N.C.)
6
OFF (continuation during power failure)
7
ON (last operation = door opening)
8
OFF (electric lock disabled in exit only mode)
9
ON (emergency operation = door opening)
10
OFF (NO door release during power failure)
11
ON (disables STOP in Night lock mode)
12
OFF (not active)
- 22 -
J13
J7
KEY
SELECTOR
JP1
DL2
BUZZER
DP1
RADAR
ON
1 2 3 4 5 6 7 8 9 10 11 12
SW2
V. AVV.
F. SPI.
T. SOS.
VELOC. % AP. P.
P2
P3
P4
P5
P6
DIP SWITCH
Trimmer
ON
OFF
Settings by DP1 DIP-SWITCH group
Position 1 (ON)
adaptative
resists
M/S disabled
equal to opening
speed*
N.C.
disabled
opens
enabled for every
closure
opens
STOP enabled
* self-learned/set with trimmer P5
group factory settings
EMR
RAD.1
RAD.2
FOTO
STOP