HANGING THE FAN
(continued)
WARNING: All set screws must be checked, and retightened where
necessary, before installation.
Step 5. Remove the hanger ball from the downrod assembly by loosening the
set screw, unscrewing and removing removing the cross pin and unscrewing
the ball off the rod. (Fig. 7)
Step 6. Loosen the two set screws and remove the hitch pin and retaining clip
from the coupling on top of the motor assembly. (Fig. 8)
Step 7. Carefully feed the electrical lead wires and safety cable from the fan
up through the downrod. Thread the downrod into the coupling until the
Hitch pin holes are aligned.
Next, replace the hitch pin and retaining clip. Tighten both set screws. (Fig. 8)
Cross Pin
Hanger
Ball
Set Screw
Download
Fig. 7
Supply Wires
Downrod
Set Screws
Retaining Clip
Fig. 8
42" , 52" and 60" Lucian II | 7
Set Screws
Hitch Pin