E N G L I S H
3.3.3. MECHANICAL STROKE SETTING & ADJUSTMENT
3.3.3.1
INITIAL STROKE SETTING
Determine Application pin stick out length in millimeters ("L" in fi gure above).
Remove battery pack from fully assembled tool.
Insert adjustment wrench into tool as shown, and engage stroke adjustment pin.
Rotate wrench counter clockwise all the way
Consult table below and based on Neobolt pin length, obtain the required ajustment value
Rotate wrench clockwise the number of rotations indicated by table above.
Remove wrench and reinstall battery.
Set part and verify tool stroke length.
Underswaged (add stroke)
3.3.3.2

STROKE ADJUSTMENT

If tool is overswaging or underswaging:
Remove battery and re-insert wrench into tool
Adjust the tool stroke by rotating the Stroke Adjustment Pin (N) to achieve the desired NeoBolt®
installation.
Each rotation of the Stroke Adjustment Pin (N) changes tool stroke by 1mm (0.04")
If underswaging - To increase the stroke, rotate Stroke Adjustment Pin (N) counter-clockwise.
If overswaging - To Reduce the stroke, rotate Stroke Adjustment Pin (N) clockwise (CW).
Verify setting by setting a part.
Repeat adjustment as needed.
12
Length (L)
Pin Adjustment (Number of Rotations)
15mm
12 full rotations (CW)
16mm
11 full rotations (CW)
17mm
10 full rotations (CW)
18mm
9 full rotations (CW)
19mm
8 full rotations (CW)
20mm
7 full rotations (CW)
21mm
6 full rotations (CW)
22mm
5 full rotations (CW)
23mm
4 full rotations (CW)
Overswaged (decrease stroke)

Publicidad