Sanitizing
14) To fill the water tank, turn the cleaning valve to the right until completely horizontal (closed).
Move the control switch to the "ICE" position, then replace the front panel. After 3.5 minutes,
remove the front panel, then move the control switch to the "OFF" position.
15) Remove the front insulation panel, then pour 50ml of an 8.25% sodium hypochlorite solution
(chlorine bleach) into the water tank. Replace the front insulation panel. Turn the cleaning
valve to the left until completely vertical (open). IMPORTANT! Use regular bleach with no
additives. Using a bleach with additives causes excessive foaming during sanitizing,
reducing the effectiveness of sanitizing.
16) NOTICE! To avoid excessive foaming, wait 1 minute before proceeding.
After 1 minute, move the control switch to the "WASH" position, then replace the front panel.
17) After 45 minutes, remove the front panel, then move the control switch to the "OFF"
position.
18) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber
hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber hose, overflow
cap, cube guide, and front insulation panel.
Sanitizing Rinse 1
19) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3.5 minutes, remove the front
panel, then move the control switch to the "OFF" position.
20) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to
the "WASH" position, then replace the front panel. After 5 minutes, remove the front panel,
then move the control switch to the "OFF" position.
21) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber
cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the water tank
has drained, reconnect the overflow pipe. Replace the rubber hose, overflow cap, cube
guide, and front insulation panel.
Sanitizing Rinse 2
22) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3.5 minutes, remove the front
panel, then move the control switch to the "OFF" position.
23) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to
the "WASH" position, then replace the front panel. After 5 minutes, remove the front panel,
then move the control switch to the "OFF" position.
24) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber
hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber hose, overflow
cap, cube guide, and front insulation panel.
18