8.3.2

Remove a clamping shell

1. Select correct clamping shell according to tube dimension (see chap. 3.8.3, p. 55).
2. Disassemble the tensioning screw:
RPG ONE (cordless): Screw out the tensioning screw (1) (flush with housing on the inside, see arrow).
RPG 1.5, RPG 2.5 (cordless): Screw out the tensioning screw (2) (flush with housing on the inside, see arrow).
3. Screw out the clamping screw (3) until it runs freely (flush with housing on the inside, see arrows).
If a clamping shell that has already been assembled needs to be replaced, it can now be removed by simply pressing on it.
RPG ONE (Cordless)
[REV. 20190314] OC_RPG_S_BA_790036765_00__INH-02_EN
2
1
RPG 1.5 (Cordless)
Setup and assembly
3
3
RPG 2.5 (Cordless)
Orbitalum Tools GmbH D-78224 Singen www.orbitalum.com