D
o not wash the outDoor unit with excessive water
shock or fire coulD result
S
i
hipping
nSpection
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and sub-
sequent investigation is the responsibility of the carrier. Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distributor
or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.
c
& R
odeS
egulationS
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibility
of the installer. The manufacturer assumes no responsibility
for equipment installed in violation of any codes or regulations.
Rated performance is achieved after 20 hours of operation.
Rated performance is delivered at the specified airflow. See
outdoor unit specification sheet for split system models or
product specification sheet for packaged and light commercial
models. Specification sheets can be found at www.amana-
hac.com for Amana products. Within the website, please select
the products menu and then select the submenu for the type
of product to be installed, such as air conditioners or heat
pumps, to access a list of product pages that each contain
links to that model's specification sheet.
The United States Environmental Protection Agency
(EPA) has issued various regulations regarding the in-
troduction and disposal of refrigerants. Failure to follow
these regulations may harm the environment and can
lead to the imposition of substantial fines.
Should you have any questions please contact our local EPA
office.
If replacing one of the component of the system, the system
must be manufacturer approved and Air Conditioning, Heating
and Refrigeration Institute (AHRI) matched.
NOTE: The installation of an inverter outdoor unit with un-
matched system units will not allow for proper operation.
NOTICE
i
outDoor unit
nverter
eev
. D
equippeD inDoor unit
with any other combination is not covereD by our warranties
Outdoor inverter units are approved for operation above 0°F
in cooling mode and -10°F (RH10%) in heating mode with no
additional kit necessary.
Damage resulting from operation of the unit in a structure
that is not complete (either as part of new construction or
renovation) is not covered by our warranties.
CAUTION
. a
n electric
.
moDels can only be matcheD with
amage resulting from operation
F
eatuReS
This outdoor unit is part of a system that uses inverter tech-
nology to more efficiently remove or add heat and achieve
the target comfort conditions. System may ONLY be installed
using an Amana approved communicating thermostat. The
Communicating system reduces the number of required
thermostat wires, provides additional setup features and
enhanced active diagnostics.
NOTICE
o
a
nly use
mana approveD communicating thermostats
a
cceSSoRieS
Name
Shape
1.5 - 3.0 ton
(ASXS6*/ASZS6*
18/24/30/361*)
3.5 - 5.0 ton
(ASXS6*/ASZS6*
42/48/601*)
Name
Shape
1.5 - 3.0 ton
(ASXS6*/ASZS6*
18/24/30/361*)
3.5 - 5.0 ton
(ASXS6*/ASZS6*
42/48/601*)
B
i
eFoRe
nStallation
Precautions to remove packaging (Corner guard)
<3.5 - 5.0 ton only>
.
• Remove the packaging
(Corner guard) used to protect
the unit while carrying from the
right front part.
Follow the steps below to remove.
1. Remove the front plate screw.
2. Remove the packaging (Corner
guard).
3. Install the front plate screw to fix the front and top
plates.
2
ASXS6S̲3P679063-2D̲ALL̲220729.pdf
Installation
Warranty
manual
card
1
1
1
1
Conduit plate
Clamp
(Φ22.2) (Φ28.6)
1
1 set
1
Front plate
screw
Front plate
Packaging (Corner guard)
.
Insulation
tube (clear)
2
Filter Dryer
1
1
Top
plate

Publicidad