Descargar Imprimir esta página

Amana ASXS61A Serie Instrucciones De Instalación página 50

Publicidad

Idiomas disponibles

Idiomas disponibles

7-S
D
egment
iSplay
SCREEN 0 (Display FAULT CODE)
Setting
No.
1
SCREEN 1 (Display FAULT CODES)
Setting
No.
1
2
3
4
5
6
SCREEN 2 (MONITOR MODE)
Setting
No.
1
Compressor operation time
2
Operation code
3
Compressor Reduction Mode
4
% Demand
5
Act % demand
6
Requested ID CFM
7
Reported ID CFM
8
Outdoor FAN RPM
9
Ta (Outdoor Air Temperature)
10
Td (Discharge Temperature)
11
Tm (Outdoor Coil Temperature)
12
Tb (Defrost Sensor Temperature)*
13
Tl (Liquid Temperature)
14
Pressure sensor (Suction Pressure)
15
Ts (Suction Temperature)
*
HP only
1
Contents
Fault code (present)
Contents
Fault code (latest)
Fault code (2nd)
Fault code (3rd)
Fault code (4th)
Fault code (5th)
Fault code (6th)
Contents
1
unit: hr (Multiply by 200)
0: Stop
1: Cooling Start-up
2: Heating Start-up*
3: Oil Return Operation
4: Heating Operation*
5: Defrost Operation*
6: Cooling Operation
0:OFF, 1: ON
unit: %
(Cut off the decimal first place)
unit: %
(Cut off the decimal first place)
unit: CFM (Multiply by 10)
unit: CFM (Multiply by 10)
unit: RPM (Multiply by 10)
unit: F
unit: F
unit: F
unit: F
unit: F
unit: PSIG
unit: F
50
50
ASXS6S̲3P679063-2D̲ALL̲220729.pdf
Notes
Notes
Latest
2nd
3rd
4th
5th
6th
Notes
1
1
1

Publicidad

loading

Este manual también es adecuado para:

Aszs61a serie