No detergent flow
Poor cleaning of the side brush
Formation of foam in the
recovery tank
Limited battery life
CHAPTER 28 - TECHNICAL SPECIFICATIONS
TECHNICAL
SPECIFICATIONS
POWER SUPPLY
MAXIMUM WORKING
AUTONOMY
CLEANING TRACK WITH
RIGHT SIDE BRUSH
CLEANING TRACK WITH
RIGHT AND LEFT SIDE
BRUSHES
WASHING TRACK
SQUEEGEE WIDTH
TURNING RADIUS
CLEAN WATER TANK
CAPACITY
DIRTY WATER TANK
CAPACITY
DETERGENT TANK
CAPACITY
SOLID WASTE CONTAINER
CAPACITY
Empty detergent tank
Detergent flow pipe clogged or bent
Blocked tank cap vent hole
Detergent pump cables disconnected or reversed
Worn peristaltic pump hose
Worn brush
Incorrectly installed brush
Use of foamy detergents
Prolonged use of MAX unit pressure
ITEM D FIG. 4
Prolonged use "ON2" ITEM E FIG. 4
Batteries discharged
Depleted batteries
-
H
MM
MM
MM
MM
MM
LT.
LT.
LT.
LT.
Fill the detergent tank
Purge the system, straighten the pipes to
remove any kinks
Clean the vent hole of the cap
Connect or reconnect the cables correctly
Replace the hose
Replace the brush
Correct the positioning of the brush
INSERT ANTI-FOAM PRODUCT INTO
RECOVERY TANKS BEFORE STARTING WORK
Use only in case of particularly dirty floor
Use only in case of particularly dirty floor
Proceed with the charging cycle and, at the
end of the cycle, check the level of distilled
water
Replace the battery pack
DUOTECH 85
24V BATTERIES
4
880
1,060
850
870
920
90
90
3
30
60

Publicidad