7.
Troubleshooting
7.1.
Fault indication in the display
Repair and maintenance work must only be carried out by Klafs service personnel or
those who are expressly authorized by Klafs to perform such work!
The fault message appears near the two right
digits of the bathing duration display (e.g. 92).
Service
The
symbol flashes together with the
fault message.
As long as the
Service
control unit is operable.
The fault message is displayed alternately with the
bathing program.
No. Error
91
The touch sensitive switch (SKS) has triggered
92
Servicing required, decalcify the evaporator
(SANARIUM C).
93
Humidity too low.
94
Humidity too high.
95
Line break actual temperature sensor.
96
Line break heater temperature sensor.
97
Safety thermostat (STB) disconnected.
98
Short-circuit actual temperature sensor.
99
Short-circuit heater temperature sensor.
PAGE 20
symbol flashes, the
Eliminate error
Remove the object from the cover over the
heater.
Service the evaporator.
'
See Chapter 8.1.
Disconnect the control unit from the mains.
Disconnect the control unit from the mains.
Do not operate the sauna any more!
Do not operate the sauna any more!
Inform the servicing personnel at Klafs.
Inform the servi ing personnel at Klafs
SANARIUM C