7.
Troubleshooting
7.2.
Further possible faults
Error
The control unit
cannot be started or
operated.
The heater will not
heat up (when
controlled via Klafs
Control or building
process control GLT).
Fan cannot be set.
PAGE 22
Cause
Additional option (PC)
appears in the display.
The control unit is controlled
by Klafs Control.
by Klafs ontrol
The operating panel is
blocked.
Additional option (key)
appears in the display for
30 minutes.
The load release of the sauna
cabin heater is requested via
Klafs Control or GLT.
Additional option (key)
does not appear in the
display.
The load release of the cabin
heater is not requested via
Klafs Control or GLT.
The 30 minute waiting period
has expired.
Climate manager is
connected.
Remedial action
Switch off Klafs Control.
.
After approx. 5 minutes, Klafs Control
releases the control unit.
Disconnect the data line between Klafs
Control and the control unit.
Remove combustible objects from the
heater!
Actuate the key switch on the sauna cabin
for 1 second within 30 minutes after start at
Klafs Control or GLT.
Request the load release of the sauna cabin
heater via Klafs Control or GLT.
Remove combustible objects from the
heater!
Actuate the key switch on the sauna cabin
for 1 second within 30 minutes after start at
Klafs Control or GLT.
.
The air flow is regulated by the climate
manager.
'
Setting the air flow - see Section 6.7.
SANARIUM C
Continued
5070188/07.02