• Example: If you set the temperature in the heating system to 20 °C and differential
to 2 °C, the thermostat activates heating as soon as room temperature drops to
18 °C and switches heating off when temperature reaches 22 °C.
• The temperature differential of the internal sensor can be set to between 0.5 °C
and 2.5 °C.
• The temperature differential of the floor sensor can be set to between 1 °C and
9 °C (EMOS GoSmart app).
Temperature Limits for Manual Thermostat Settings
• Maximum temperature setting limit – specifies the maximum temperature that
can be set on the thermostat (20 °C to 70 °C, 1 °C resolution).
• Minimum temperature setting limit – specifies the minimum temperature that can
be set on the thermostat (1 °C to 20 °C, 1 °C resolution).
Temperature Protection
• High-temperature protection – specifies the maximum temperature the thermostat
heats the system up to.
• Example: When temperature protection for the sensor is set to 45 °C and the limit
to 2 °C, the thermostat relay switches off if temperature exceeds 45 °C and turns
on again if temperature drops to 43 °C.
• Low-temperature protection – specifies the lowest possible room temperature. If
the temperature drops below the set value, the thermostat will start automatically
heating up the room. Can be set to between 1 °C and 10 °C.
Status of the Device after Reconnecting to Power after a Power Outage
• The same as before turning off – the thermostat returns to the state it was in
before the power outage.
• Off – the thermostat stays off after reconnecting.
• On – the thermostat turns on after reconnecting.
Active Temperature Sensor
• The setting defines which sensor is detecting temperature – either the internal
sensor, floor sensor or both.