Descargar Imprimir esta página

Integrity I Fuse 105 Manual Del Usuario página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

4)
Technical data and dimensions
Technical data
CEI EN 60335 – 1 Classification
ISO 12176-2 Classification
Max Working Range
Fusable Materials
Transfer fusion parameters
Input Voltage
Input Current
Input frequency
Output Voltage
Output Current
Output Peak
Nominal power
Working temperature range
Protection
Weight (cables included)
Input cable
Output cable
Welding Terminals
Display
Monitoring Functions
Input
Output
Other
Error messages
Kit
I Fuse 60
P2 3 U S2 V AK D X
400 mm / 16" IPS + DIPS
120 V AC, (102 V – 138 V)
32 A
50 Hz (40 – 70 Hz)
100% = 50A
60% = 70A
30% = 90A
100 A (electronically limited)
2500 W
18 Kg / 40 lbs.
Length 4,0 m / 13≅ ft
NEMA L5-30 125V/ 30A Twist Lock Plug
graphic, 128x64 Characters ( alphanum.), background lighting
Voltage / Resistance / Contact / Short Circuit / Current
Software / Working Temperature / Service
USB Memory Drive, Transport Case, User Manual
Pag. 9/50
Electronic device in Class I
PE / PEX / PP / PP-R
Scanner / Manual
8 - 48 V AC
65 A
-10 °C + 50 °C / 14 °F to 113 °F
IP54
NEMA L14-30 250V/ 30A Twist Lock Plug
3,0 m / 10≅ ft
4,0 mm (4,7 mm adapters)
Voltage / Current / Frequency
Plain Text / Acoustic Signals
I Fuse 105
P
4 U S
V AK D X
2
2
1.200 mm / 48" IPS
230 V AC, (185 V – 260 V)
16 A
50 Hz (40 – 70 Hz)
20000 sec. – 105 A max 1400 sec.
>
@ 20 °C / 68 °F
120 A (electronically limited)
3600 W
24 Kg / 53 lbs.
Length 4,0 m / 13≅ ft

Publicidad

loading

Este manual también es adecuado para:

I fuse 60