1. HANDLING
The VERTINOX 1,2,3,4,5,10,15 and 20 pump motors are supplied with rings which must not be used to
lift the entire pump.
If the entire pump is to be lifted, please note the following:
VERTINOX 1,2,3,4,5,10,15 and 20 pumps equipped with standard motors must be lifted by the pump
head by means of belts or similar.
VERTINOX 32, 45, 64 and 90 pumps, equipped with standard motors up to and including 11 kW, must
be lifted by means of the ring mounted on the pump head.
VERTINOX 32, 45, 64 and 90 pumps equipped with motors of 15 kW and above must be lifted by
means of the eyebolts mounted on the motor bracket.
For other motor models than those mentioned above, it is recommended to lift the pump by the
pump head using belts.
2. NOMENCLATURE
Example:
3. APPLICATIONS
The VERTINOX stainless steel vertical multistage centrifugal pump is designed for a wide range of
applications.
3.1. Features.
Features: high efficiency, low noise, compact structure, small size, light weight, optimal design, reliable
seal, easy operation, etc.
www.proindecsa.com / proindecsa@proindecsa.com
VERTINOX 2 - 11
Model
Flow rate (m3/h)
Impeller number