OPERATING AND MAINTENANCE MANUAL
VERTICAL ELECTRIC PUMP VERTINOX SERIES
11. MAINTENANCE
Before starting work on the pump, make sure that all power supplies to the pump are switched off and
that they cannot be switched on accidentally.
of the pump are switched off and that they cannot be switched on accidentally.
The pump bearings and shaft seal are maintenance free.
Engine bearing
Motors that are not equipped with grease nipples do not require maintenance. Motors fitted with grease
nipples must be lubricated with high temperature lithium based lubricants. See instructions on the fan
cover. In case of seasonal operation (the motor is idle for more than 6 months of the year), it is recom-
mended to lubricate the motor when the pump stops operating.
pump stops operating. Installing the pump according to the instructions allows the pump to work effi-
ciently and requires less maintenance.
Self-adjustment of the mechanical seal, lubrication and cooling of the interface between the statio-
nary ring and the rotating ring by the pumped liquid.
Sliding bearing lubricated by the pumped liquid.
12. FROST PROTECTION
Pumps that are not used during frosty periods must be drained to prevent damage.
avoid damage.
Drain the pump by loosening the vent screw on the pump head and removing the drain plug from the
base. Care must be taken to ensure that escaping water does not cause injury to persons, the engine or
other components. In hot water installations, special attention must be paid to the risk of injury caused
by hot water. Do not tighten the venting screw and replace the drain plug until the pump is used again.
VERTINOX 1, 2, 3, 3, 4, 5
Before replacing the drain plug in the base, unscrew the bypass valve outwards against the stopper. Fill
the drain plug by tightening the large union nut followed by the bypass valve.