BIR 01- _ _ _ _ -K15SL _-000S15
Inductive Rapid Positioning System
10
Technical data
The specifications are typical values for
BIR 01- _ _ _ _ -K15SL _-000S15 at 24 V DC, room
temperature and a nominal length of 500 mm in
conjunction with the targets BAM TG-IR-036-A,
BAM TG-IR-036-B, BAM TG-IR-037-A and
BAM TG-IR-037-B.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
10.1
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Typ. temperature coefficient
2)
Shock rating as per
EN 60068-2-27
3), 4)
Continuous shock per
EN 60068-2-27
3), 4)
Vibration per
EN 60068-2-6
3), 4)
Protection per IEC 60529
(when threaded together)
10.2
Detection range/Measuring range
Measuring length
5)
Resolution
Repeat accuracy
Measuring frequency
Non-linearity
Detectable speed
10.3
Electrical data
Operating voltage U
b
Current draw
(at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to
(GND – Housing)
www.balluff.com
1)
−40...+85 °C
−40...+85 °C
≤ 95%, non-condensing
≤ 30 ppm/K
100 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
IP67
200, 300, 500 and 600 mm
1 µm
< 1 µm
≥ 10 kHz
≤ ± 100 µm
≤ 10 m/s
10...30 V DC
≤ 70 mA
≤ 2.0 W
U
to 36 V
b
500 V DC
10.4
Electrical Connection
Short circuit
to GND and 36 V
protection
Reverse polarity
U
to 36 V
b
protected
6)
10.5
Output / interface
10.5.1 SSI interface
Configurable bit
16-32
number
Coding
Binary oder Gray
Characteristic
Rising or falling
SSI-data
Position, error value
SSI clock frequency f
10 kHz...1 MHz
Clk
Short-circuit protection Signal lines Data+/–, Clk+/– to
+36 V or GND
10.5.2 IO-Link interface
Transfer protocol
1.1
Transmission rate
COM3 (230.4 kBaud)
Cycle time
≥ 1 ms
Output value
Position in µm
Data format
32 Bit signed
Error value
0x7FFFFFFC
10.6
Materials
Housing material
Anodized aluminum
Plastic (PBT-GF30)
Material, active
Plastic (PBT-GF30)
surface
10.7
Mechanical features
Weight (depends on
Approx. 2 kg/m
length)
Housing mounting
Mounting clamps and screws
Tightening torque
2 Nm
For UL: Use in enclosed spaces and up to an altitude of 2000 m above
1)
sea level.
Measuring length 500 mm, target in the middle of the measuring range
2)
Individual specifications as per Balluff standard
3)
Resonant frequencies excluded
4)
Currently available measuring lengths: 200 mm, 300 mm, 500 mm,
5)
600 mm. Other measuring lengths in 100 mm increments are available on
request.
For UL: The BIR must be externally connected via a limited-energy circuit
6)
as defined in UL 61010-1, a low-power source as defined in UL 60950-1
or a class 2 power supply as defined in UL 1310 or UL 1585.
english
21