Descargar Imprimir esta página

Casselin CFRPC43 Manual De Instrucciones página 38

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SAFETY THERMOSTAT
The safety thermostat is located inside the ventilation chamber, right next to the burners. It is calibrated at 427°C and
is manually reset. If the same or higher temperature is detected, the entire oven is turned off and the gas is turned off.
To restart the oven, a qualified technician must intervene, who will verify the reason for this anomaly and then can only
reset it manually by opening the panel of the technical compartment (system door). See the figure below where the
safety thermostat is highlighted.
The position of the red reset button is indicated by the arrow.
Reset is only possible when the chamber temperature has fallen below 427°C.
As the safety thermostat is only triggered in the event of a serious fault, before restarting the
oven, carefully check its operation and carry out any repairs.
RESET
8

Publicidad

loading

Este manual también es adecuado para:

Cfrpc86Cfrpc137Cfrpc206