11 Dismounting
Fault
Spraying function is not
switched on/off
Spraying unit is leaking
Tab. 9
Troubleshooting
11 Dismounting
12 Disposal
12.1 Materials
EN - 12
Cause
• Output signal is active
• 5/2-way valve without function
• Screwing untight
• Improper mounting
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• De-energize the work area of the robot.
NOTE
• Observe the information given in section 8 Putting out of operation on
page EN-10.
 Fig. 4 on page EN-8
1 Unscrew the cylinder screws (2) .
2 Remove parts to be disconnected.
For disposal, the local regulations, laws, provisions, standards and guidelines
must be observed. For the product to be properly disposed of, it first must be
dismounted.
 11 Dismounting on page EN-12
This product is mainly made of metallic materials which can be molten in steel
and iron works and are thus almost infinitely recyclable. The plastic materials
Front Injector TMS-VI
Solution
• Check system control
• Replace 5/2-way valve if
required or check control line
• Retighten
• Mount on a vibration-free flat
mounting surface as specified