2.7.4 Hazardous materials
Incorrect handling of the device, the accessories or non-compliance with the processes
described in the Operating Instructions may lead to contact of the user with uncured
material or the cleaning agent isopropanol (isopropyl alchohol). This may results in
health damages, e.g. skin irritations.
Depending on the material, there is a risk of skin irritations, allergic reactions or
respiratory diseases without the corresponding safety precautions.
If the cleaning agent isopropanol is used incorrectly, there is also a risk of explosion and
fire.
f Observe the Instructions for Use of the materials used ("Documents of equal
applicability and required files", page 5).
f Wear protective gear ("Personal protective equipment", page 8).
f Make sure that the room is sufficiently ventilated when working with the materials or
handling the material bottles.
f Only use mild, pH neutral cleaning agents for cleaning.
2.8. Safety information for the individual operating
phases
2.8.1 Transport
f Transport the device only as described in the Operating Instructions (see
requirements regarding transport and setting up in the Operating Instructions,
"Documents of equal applicability and required files", page 5).
f In order to avoid corrosion on the device and subsequent damage to the device,
transport and store device only in the permissible temperature range and ambient
conditions (see requirements regarding the ambient conditions in the Operating
Instructions, "Documents of equal applicability and required files", page 5).
2.8.2 Initial operation
f Ensure that this device is only operated by authorized and trained specialists.
f If the device has been stored in a cold environment or at high humidity, maintain a
drying or temperature adjustment time of approx. 1 hours (without voltage) at room
temperature before initial operation.
f Before connecting the device, check that the supply voltage and frequency are
correct at the point of installation (see electrical data in the Operating Instructions,
"Documents of equal applicability and required files", page 5).
f The requirements regarding the location site and ambient conditions must be
observed (see requirements regarding the location site and ambient conditions in the
Operating Instructions, "Documents of equal applicability and required files",
page 5).
2.8.3 Operation
f Ensure that this device is only operated by authorized and trained specialists.
f Keep unauthorized persons, such as patients and children, as well as animals away
from the unit.
f In all cases of doubt regarding the safety of the device, switch off and disconnect the
device and take suitable measures to prevent further use.
f Prior to connecting power or operation, check the device, the accessories and
protective equipment for any damage.
f Do not use damaged, non-functioning equipment or accessories; instead notify your
authorized service partner.
f In order to ensure the product safety and warranty services, the device must be
exclusively operated with the original accessories from Ivoclar, particularly the original
power cord. The user bears the risk when using non-approved accessories.
f Ivoclar recommends using only approved materials to ensure process reliability.
f Never bypass the safety equipment of the device or set it out of operation ("Working
areas, potential hazards and safety measures on the device", page 8).