Descargar Imprimir esta página

Sagola HTV 250 Manual De Instrucciones página 29

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
28/29
9
4
7
8
Fig.02
06. Warnings
Before putting the unit into operation, we recommend that you clean the equipment as this has
been subjected to functional tests and before packaging it is treated internally with a protective
coating, some of which may still remain. Apply solvent to eliminate this. Remove any residual
grease applied during assembly.
The unit is supplied depressurised (without pressure inside).
Before starting up and especially after each cleaning and/or repair procedure, you must check
that the components of the unit are perfectly tightened and that the hoses are technically suited
to the features of the equipment and the work to be carried out, in addition to being flexible and
sealed (without leaks). Faulty parts must be replaced or repaired as appropriate.
Check that the unit's safety devices work properly before using it.
The unit is easy to handle thanks to its design and the simplicity of its mechanisms. Use it accor-
ding to the operating, maintenance and safety instructions indicated in this manual and follow the
application methods indicated to obtain the required finish quality.
USE ANTISTATIC AIR HOSES. SHOULD AN ANTISTATIC AIR HOSE NOT BE
AVAILABLE, YOU MUST ATTACH THE UNIT TO A GROUND CONNECTION IN
ORDER TO ELIMINATE ANY STATIC ELECTRICITY.
You must always connect the equipment and all the elements involved in the work
process to a grounding connection to eliminate static electricity. Regularly verify (one a
week) its electrical continuity. If its resistance exceeds the recommended limits, it must
be fixed. An equipment unit without or with a faulty grounding connection may make
the installation dangerous.
The total derivative resistance must be <1 million Ohms (Ω).
5
3
ENGLISH
10
1
2

Publicidad

loading