18. Troubleshooting
MALFUNCTION
The unit does
not start
The Unit
does not suck in
any product
NOTE: The symbol (*) means that before starting the procedure it is necessary to release pressure (see
paragraph 10.1)
CAUSE
Compressed air supply
malfunctioning
Malfunction in the pneumatic system Consult S.A.T. SAGOLA
Pressurised unit
The product container is empty
The suction Filter is obstructed
The suction Probe is loose, blocked
or damaged
The pressure Regulator is set at
minimum
The purge Valve is closed
The suction Probe is stuck, dirty or
damaged
Gaskets in poor condition
The hydraulic mechanism is loose or
faulty
ENGLISH
REPAIR
Make sure the supply hose
is not obstructed.
Make sure the unit is
properly connected to the
mains supply.
Make sure the compressed
air valve is Open (*)
Depressurise the unit (*)
Refill it
Replace or clean. (*)
Check the connection of the
probe to the unit or replace it
Increase the pressure by
adjusting the
regulator.
Open it (*)
Replace or clean. (*)
Replace (*)
Tighten it or replace