For automatic cleaning of the gun, tools and accessories used in the mixing and preparation of
the product to be applied, we recommend the use of SAGOLA Washing Machines.
The gun can be cleaned with thinners or detergents in a gun washing
machine.
If you opt for this cleaning system, we advise you to remember the following considerations,
which, if not applied, may damage the gun and render the warranty null and void:
Do not submerge the gun in solvent or detergents longer than the
time required for cleaning.
Do not use the gun immediately after cleaning has been completed.
Ensure that there is no thinner or detergent inside and that it is
completely free of these. Other cleaning systems can be used
(ultrasound).
Antipulsations filter (HTV 250 part list No.27)
1. Empty the product from the equipment and perform the decompression procedure.
2. Unscrew the cover of the antipulsations filter.
3. Extract the product filter (HTV 250 part list No.30) and clean it with the suited solvent or
replace it if necessary.
4. Assemble the product filter.
5. Assemble, by tightening to the utmost, the cover of the antipulsations filter.