1.2- Technical specifications
1.2.1- Equipment
1.2.2 – Common characteristics on the PRO units
Adjustment of chlorine production by switched mode power supply
Power supply performance >90%
Automatic switch-off owing to lack of water flow
Automatic voltage adjustment depending on the concentration of salt and the
temperature, keeping continuous chlorine production.
Automatic cleaning cycle of electrodes.
Automatic restart in the event of supply failure.
1.3- Recommendations and safety precautions
The equipment should always be installed by qualified staff.
Disconnect the equipment from the mains before performing any assembly or
maintenance operation.
Make sure that the electrical installation has all compulsory protection elements
(circuit breaker and differential switch) in perfect condition.
It is important to ensure that the supply cables of the electrolysis cell are tightly
connected, otherwise the equipment could overheat and break down.
Ensure that the heatsink wings are not blocked and that air can easily circulate
through them.
BSV PRO equipment incorporate protection systems against short circuits in the
cell, absence of water detector and other safety systems that give an acoustic
Manual PRO200V2 V2
Models
PRO200V2
Supply
230Vac
voltage
50/60Hz
Chlorine
production
200
g/hour
Max. power
1350W
Cell current
36A
300x250x230m
Dimensions
m
Weight
6Kg
Protection
IP65