Select this mode only if you have an ORP or Amperometric probe kit. If you do
not have a probe, the equipment will act at random and end up by stopping
and showing an error.
This mode enables you to automatically adjust the level of chlorine in your
swimming pool. Based on the adjusted set value in the "chlorine" menu, the
equipment will stop when it reaches this value, and start-up again automatically
when there is a need for chlorine.
4.1.2.1.3- Cleaning
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.
The time between cleaning (in hours) can be adjusted depending on the water
hardness of your swimming pool.
It is possible to select cleaning intervals from 1 to 8 hours.
4.1.2.1.4 Acid / Alkali
With this option you can select the type of pH corrector to be used in your
swimming pool.
Attention: It should be selected correctly otherwise the
dosing system will work opposite to expected.
Acid: Select this mode if you are going to inject pH reducer into the swimming
pool (default mode).
Alkaline: Select this mode if you need to inject pH increaser into the swimming
pool.
Access this option from the "Configuration menu". To change this mode to
another one, press OK and confirm the change of mode by selecting "S" and
then press OK again.
Note: Password "1234" is required to modify this function.
47 / 53
Manual PRO200V2 V2