In the event of abnormal operation, the SMART series equipment will display an
alarm message on the 4th line of the screen, together with an acoustic warning.
The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a warning also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.2.1- Warning messages
Message:
"LACK OF SALT"
"EXCESS SALT"
"CLEANING"
"TEMPERATURE".
4.2.2- Alarm Messages
In the following cases, the chlorinator shuts down and the alarm and
acoustic alarm LED is activated (automatic reset once the fault is solved):
"NO WATER FLOW"
Manual PRO200V2 V2
Causes:
Lack of salt in the water.
Incrustations or objects in the
electrolysis
cell
excess current.
The electrolysis cell is worn.
Excess salt in the water.
Incrustations or objects in the
electrolysis
cell
excess current.
The chlorinator is in the self-
cleaning process. The process
lasts 5 minutes
The ambient temperature is
>40º
The
radiator
fins
obstructed or are not in a
vertical position.
Excess gas in the electrolysis
cell. It may have occurred
because
the
pump
shutdown.
The
gas
hydrogen gas which is highly
flammable.
Action required:
Add salt to the swimming pool.
Clean the cell.
causing
Replace the electrolysis cell with a
new one.
No action required if excess is not
very significant.
Clean the cell.
causing
None.
Try and place the equipment in
another position where it is not
over
40º
ventilation. Leave the equipment
to rest for a few minutes.
Consult section number
4. Installation
are
Place the equipment so that air is
circulated for correct cooling.
The piping should be drained to
eliminate gas or accumulated water.
has
Check the pump.
is
or
perform
forced
51 / 53