Descargar Imprimir esta página

BSV PRO200V2 Manual De Usuario página 48

Publicidad

Idiomas disponibles

Idiomas disponibles

4.1.2.1.5- pH Alarm
The pH adjustment system will give an alarm and the dosing pump will stop
operating when the pump works continuously for more than 2 hours,
This could occur for the following reasons:
The acid tank is empty and therefore pH corrector is not being injected into the
swimming pool.
The pH probe is dirty or worn, and cannot read the real value correctly.
However, what could occur, particularly when starting up the equipment for the
first time, is that the real pH of the water is a long way from the set value. The
alarm can be disabled if it is calculated that the pump needs to work
continuously for several hours to correct the pH. However it is recommended to
enable the alarm once values near the set values are reached.
Note: Password "1234" is required to modify this function.
4.1.2.1.6 Chlorine/ORP Alarm
When the unit is configured in automatic mode, it is possible to disable the
"Chloride Alarm". This alarm will detect if the ORP or PPM reading hasn't
changed for two hours or more, despite the unit has been in production.
Despite this alarm has been implemented to detect if a probe is not in good
conditions, or there is some chemical issue in the water, it can be disabled if
the user wants to maintain the production despite everything.
Note: Password "1234" is required to modify this function.
4.1.2.1.7 Buzzer
When an alarm occurs, the unit stops its production and shows an acoustic and
visual alarm to indicate that it's necessary to correct the problem.
However, it is possible to configure the acoustic signal with the following
options:
No: Acoustic alarm is disabled
24h: Acoustic alarm is activated 24h.
Adjustable: The user can adjust the time range where the buzzer is active in
case of alarm.
Note: In case of alarm, the unit will stop its production and will show the cause
on the display, regardless of the acoustic alarm configuration.
4.1.2.2- Chorine menu
With this menu you can select all parameters related to chlorine production.
48 / 53
Manual PRO200V2 V2

Publicidad

loading