Kits input connector: sonda agua, NTC, AUTO, ADVANCED, PRO/2
1- Kit NTC / Conductivity Probe (White)
2- Kit NTC
3- Flow Switch
4- Flow Switch
5- ORP Probe (ORP-)
6- ORP Probe (ORP+)
7- Free Chlorine Probe (IN)
8- Free Chlorine Probe (24V
9- (Black)
10- (Green)
11- (Brown)
3) ORP and Free Chlorine Probe configuration.
Set jumper positions of JP2 connector as picture shows to configure each probe
reading.
ORP:
Free Chlorine:
4) Start/Stop configuration
Remove jumper from JP1, check figure 3.3 to find its location. Connect from
filtration pump contactor output to filter input connector 220VAC cables.
PRO200V2 will work with Start/Stop configuration. When filtration pump is on,
Salt water chrlorinator will start production. PRO200V2 will stop when filtration
pump switches off. On main screen will be displayed "Stop" message.
Filter input consumption will be a few milliampers.
42 / 53
Manual PRO200V2 V2