TABELLA "B" MENU LOGICHE (logic)
LOGIC
DEFINITION
Automatic closing time
TCA
Panic opening (battery)
antipanic
(LOGIC 83)*
ra blow
Hammer during opening
c. o p
Open in other direction
Inv. dir.
Configuration of safety input
SAFE 1.
(Fig. S1, S2, S3, S4)
SAFE 1
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Configuration of safety input
SAFE 2.
(Fig. S1, S2, S3, S4)
SAFE 2
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Configuration of safety input
SAFE 3.
(Fig. S1, S2, S3, S4)
SAFE 3
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Configuration of safety input
SAFE 4.
(Fig. S1, S2, S3, S4)
SAFE 4
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Multifunction input
ultifunc.
operating mode
input
Door state output
door
operating mode.
status
Locking device
type of
operating mode
loc
Fixed Code
fixed code
28
- VISTA-SL (ARIA-EVO 2015)
INSTALLATION MANUAL
Cross out
using
DEFAULT
setting
1
1
Automatic Closing ON/OFF (TCA and Clear Time)
0
1
0
Panic Feature ON/OFF (Section ANTI-PANIC FUNCTION)
0
1
0
Hammer ON/OFF during opening
0
1
Change this parameter if the opening direction needs to be changed. Fig. AK
0
Standard operating mode. Fig. AK
0
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
0
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
2
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
0
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input configured as active safety during opening.
0
Input configured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input configured as active safety during closing.
2
2
Input configured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input configured as active safety during opening with "detection zone".
4
Input configured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
0
1
Multifunction type []- Set the multifunction input operating mode.
0
2
(Par. MULTIFUNCTION INPUT OPERATING MODE)
3
4
0
Door state output mode []. Sets the DOOR STATE output's operating mode
0
(Sect. DOOR STATUS OUTPUT OPERATION MODE)
1
0
1
2
3
4
Lock mode []. Sets the locking device's operating mode
1
(Sect. LOCKING DEVICE OPERATION MODE)
5
6
7
8
9
1
ON:
Receiver is configured for operation in fixed-code mode.
0
OFF: Receiver is configured for operation in rolling-code mode.
0
DESCRIPTION