4.4
Conformity to international standards
4.4.1
Electrical safety (in accordance with IEC 1010-2-032)
- Dual insulation
- Installation category III
4.4.2
Electromagnetic compatibility
■ Emission: class B (i.a.w. EN 50081-1)
■ Immunity: (i.a.w. EN 50082-2)
-
Electrostatic discharge (i.a.w. IEC 1000-4-2) :
4 kV in contact - level 2 - capability criterion B
8 kV in air - level 3 - capability criterion B
-
Radiated electromagnetic energy (i.a.w. IEC 1000-4-3) :
10 V/m - level 3 - capability criterion A
-
Short-duration transients (i.a.w. IEC 1000-4-4) :
2kV - level 3 - capability criterion B
-
Power frequency magnetic field (i.a.w. IEC 1000-4-8) :
30 A/m - level 4 - capability criterion A
4.4.3
Mechanical protection
- Degree of protection IP20 (i.a.w. IEC 529) with jaws closed
- Free fall: 1.5 m (i.a.w. IEC 68-2-32)
- Shock: 100 g (i.a.w. IEC 68-2-27)
- Vibration: 0.15 mm - 10/55/10 Hz (i.a.w. IEC 68-2-6)
4.4.4
Flammability rating
- VO (i.a.w. UL 94)
- Pollution degree 2
- Working voltage: 600 V rms
16