Descargar Imprimir esta página

MBM CPE94T Manual De Uso E Instalación página 32

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
nuts (part H1-H3).
Replace the protective caps between
the devices (part H2).
Repeat, if necessary, the sequence of
leveling and fixing operations for the re-
maining equipment.
INTRODUCTION
Before proceeding with the
operations, see "General sa-
fety information".
These operations must be per-
formed by qualified and au-
thorised operators, in accord-
ance with the laws in force and using
the appropriate materials described.
Generally the appliance is de-
livered without electric mains
supply cable, without pipes
for connection to the water, drain-
age and gas networks.
CONNECTION OF WATER SUP-
PLY / see SECT. IMAGES - REF. d)
Make sure these conditions are sati-
sfied to obtain a correct installation:
The equipment must be supplied
1.
with tap water with a working pres-
sure included from 200 kPa up to
400 kPa and it must also ensure a
minimum flow rate of 1.5 l/min.
The water entry pipe must be con-
2.
nected to the distribution network
through a cutoff cock (easily re-
cognizable and ac-cessible by the
operator) that must be closed when
the ap-pliance is not working or
during maintenance interventions
(Fig. 1).
Install a mechanical filter between
3.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POSITIONING AND HANDLING
OF
TERMINAL
POWER SUPPLY CONNECTIONS
- 10 -
(OPTIONAL) / see SECT. IMAGES
- REF. c) / In order to introduce the
terminal, position it and fix it with the
equipped screws provided (detail L1).
Once the described operations have
been carried out, position again the
panels and knobs of the different ap-
pliances in the respective housings.
the cutoff cock and the appliance
connection pipe, in order to pre-
vent the introduction of any ferrous
dross, which oxidize, and which
therefore could corrode and with
time cause the oxidation of the tank.
It is advisable before con-
necting the last section of the
attachment to allow the outflow
of a certain amount of water to flush
the pipe of any ferrous slag.
Connect one end of the supply pipe
to the attachment of the appliance
(Fig. 2);
Connect the other end of the pipe
provided with filter to the check val-
ve (Fig. 3-3F).
Open the check valve and visual-
ly check the tightness of the con-
nection (Fig. 4).
WATER SPECIFICS /
See technical data table
CONNECTION TO GREY WATER
DRAINAGE SYSTEM / see SECT.
IMAGES - REF. d)
A correct installation requires the fol-
lowing conditions:
The connection to the drain into the
system must be "OPEN, WITH NO
TRAP" and the material for pipe fit-
ting and containment must support
4.

Publicidad

loading

Este manual también es adecuado para:

Cpe74aCpe77aCpe77tCpe98tCpe94aCpe98a