2
Operation and Features
4 Enable the OCP.
To cancel this operation, allow the unit to idle for five seconds.
NOTE
Disable the OCP
1 Select an output channel with OCP enabled.
2 Disable the OCP.
56
– Press the [Over Current] button again to end the adjustment and enable
the OCP.
– The display will show dOnE.
– The corresponding OCP annunciator (OCP1 or OCP2) turns on.
– Press [1] to select Output 1, or
– Press [2] to select Output 2.
– The corresponding annunciator (OUT1 or OUT2) turns on.
– Press the [Over Current] button again to disable the OCP.
– The corresponding OCP annunciator (OCP1 or OCP2) turns off.
Keysight U8030A Series User's Guide