DESCRIPTION OF THE PRODUCT
2

OPERATOR FEATURES

Model
Power supply (V/Hz)
Absorbed current (A)
Power consumed (W)
Capacitor (μF)
Protection class (IP)
Maximum torque (Nm)
Maximum speed (m/min)
Locking
Operating temperature (ºC)
Duty cycle S3 (%)
Weight (Kg)
Maximum weight of gate (kg)
General features
• Power supply (earthed):
RIS600EC, RIS1000EC: 230Vac/ 50Hz
RIS600ECM, RIS1000ECM: 125Vac/ 60Hz
• Control of the open/close by way of encoder
• Adjustable maximum thrust
• Adjustable standby time in automatic cycle
• Opening and closing safety device cable connectors
(photocells or mechanical strips)
Notable features
Self-testing of photocells (programmable)
The control panel tests the photocells before starting
each operation. Should a failure be detected, the
operation is not carried out.
Garage light (programmable)
The garage light time can be programmed between 3
and 90 seconds. Time begins to count when operation
starts.
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Operation advance warning function
(DIP2=ON)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
48
Installation Guide
RIS600EC
RIS1000EC
230/50
230/50
1,2
1,7
280
390
10
12
44
44
20,4
27
11,4
11,4
Yes
Yes
-20/ +55
-20/ +55
30
50
13
14,5
600
1000
RIS600ECM RIS1000ECM
125/60
125/60
2,3
2,7
275
300
40
50
44
44
20,4
27
13,7
13,7
Yes
Yes
-20/ +55
-20/ +55
30
50
13
14,5
600
1000
• Cable connector for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card
• 24Vdc cable connector for peripheral connection
• Self-testing of photocells
Traffic light
A plug-in receiver can be connected if the AEPS1-001
card is installed. Using colour lights, these will indicate
the suitability or otherwise of crossing the gate.
• Off: gate closed
• Green light: gate open, free passage
• Red light: gate in movement, passage forbidden
• Flashing green light: open gate about to close (in
automatic mode)
Slowdown function (DIP 8=ON)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
STOP pushbutton (emergency stop)
This contro l pa nel allows an emergency stop
pushbutton to be installed (STOP). This pushbutton is of
NC type (normally closed). The opening of this contact
produces the immediate halting of the gate.
R I N O
o p e r a t o r s
a r e
constructed to form part
o f
a
s l i d i n g
g a t e
automation system.
This operator, with built-in
control panel, is equipped
with a slowdown system
which reduces speed at
the end of the opening
and closing operations, in
order to prevent impacts
and bangs to the gate.
This operator allows us to
fulfil the requirements of
s t a n d a r d
E N 1 2 4 5 3
w i t h o u t t h e u s e o f
peripheral elements.