Descargar Imprimir esta página

EBARA 3TSM ci Manual De Instrucciones página 44

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTRUCTION MANUAL
Models
3TSM ce/8
3TSM ce/11
3TSM ce/13
3TSM ce/17
3TSM2-17 ce 1100W
3TSM3-12 ce 1100W
3TSM2-23 ce 1500W
3TSM3-17 ce 1500W
3TSM2-37 ce 2200W
3TSM ci/8
3TSM ci/11
3TSM ci/13
3TSM ci/17
4TSM2-12 ci 1100W
4TSM6-11 ci 1500W
4TSM4-15 ci 2200W
4TSM6-14 ci 2200W
4TSM8-10 ci 2200W
5. Electronic controller
Nomenclature
- Models with internal electronic controller: 3TSM ci, 4TSM2, 4TSM4, 4TSM6 and 4TSM8 ci.
- Models with external electronic controller: 3TSM ce, 3TSM2 and 3TSM3 ce.
Operating principle
Photovoltaic panels convert sunlight energy into electrical energy (direct current). The electronic controller
stabilizes the input voltage (Vdc) and creates a three-phase direct current output to start the motor pump.
Functions of the electronic controller
I. Undervoltage protection (automatic) - All models;
II. Overcurrent protection (automatic) - All models;
III. Phase loss protection - All models;
IV. Blocked rotor protection - Models: 3TSM2, 3TSM3, 4TSM2, 4TSM4, 4TSM6 and 4TSM8;
V. Protection for low water level in the well (dry well sensor) - only for external controller models;
VI. Tank overflow protection (tank level sensor) - only for external controller models;
VII. Preventive shutdown against dry operation - Models: 3TSM2, 3TSM3, 4TSM2, 4TSM4, 4TSM6 and
4TSM8;
VIII. MPPT function with automatic maximum power point tracking - All models.
44
Solar Power Cable
4 mm²
35
60
100
100
125
125
190
190
250
35
60
100
100
125
190
250
250
250
Table - Cable length limit at installation
EBARA BOMBAS AMÉRICA DO SUL LTDA.
3TSM ci/ce and 4TSM ci
Maximum length (m)
Solar Power Cable
6 mm²
50
95
145
145
190
190
300
300
400
50
95
145
145
190
300
400
400
400
Models
Level Sensor Cable
1.5 mm²
200
-

Publicidad

loading

Este manual también es adecuado para:

3tsm ce4tsm ci