Descargar Imprimir esta página

EBARA 3TSM ci Manual De Instrucciones página 50

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTRUCTION MANUAL
5.2.2.1 External controller models 3TSM
Note: the other
keys are not
used.
• In normal situation, Power, MPPT and V (voltage) indicator lights are on at the same time;
• If there is no water in the well, the MPPT indicator light will turn off. Then the well indicator light (Well) will
turn on and the motor will stop operating;
• If the tank is full, the MPPT indicator light will turn off. Then, the tank indicator light (Tank) will turn on and
the motor will stop operating.
Description of fault codes
When a fault occurs, the motor will shut down and the corresponding fault code will appear on the controller
display.
50
Figure - Controller Operation Panel
Fault
Damaged transistors
Motor phase loss
Overcurrent
Undervoltage / Overvoltage
Stuck impeller
Abnormal temperature
Table - Fault codes