5.2.2 Menu BASIC - Basic Application

Seq
Indication on the Display/Action
1
Monitoring mode. Press the key ENTER/
M E N U to e n te r t h e 1
programming mode
3
When the BASIC group is selected press
the key ENTER/MENU
5
If necessary, modify the content of "P0101
- Deceleration Time"
Press the key
7
If necessary, modify the content of "P0134
- Maximum Speed"
Press the key
9
To end the Start-up routine, press the key
BACK/ESC
To return to the monitoring mode, press the
key BACK/ESC again
l e ve l of t h e
s t
for the next parameter
for the next parameter
Figure 5.4: Sequence of the basic application group
Powering up and Startup
Seq
Indication on the Display/Action
2
The PARAM group is selected, press the
keys
or
group
4
Basic Application routine is started. If
necessary, modify the content of "P0100 -
Acceleration Time"
Press the key
6
If necessary, modify the content of "P0133
- Minimum Speed"
Press the key
8
If necessary, modify the content of "P0135
- Maximum Output Current"
Press the key
until selecting the BASIC
for the next parameter
for the next parameter
for the next parameter
CFW500 | 33