SIMPLE LOGGER II
MODEL
Electrical
Channels
Input
Range
Accuracy
(50/60Hz)
Resolution
Sample Rate
Storage Rate
Storage Modes
Recording Length
Memory
Communication
Power Source**
Battery Life
Mechanical
Dimensions
Weight (with battery)
Sensor/Cable Length
Case
Vibration
Shock
Drop
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Safety & Electro-magnetic compatibility
Safety Rating
Protection Degree
Electro-Magnetic Compatibility
CE Approved
*This specific recording mode has the advantage letting recording continue for a long period, but at the
expense of the data storage rate. Each time the memory becomes full, in the XRM
of data already recorded is erased, making room for new data. The rate of recording of the new data is
slowed accordingly. This process continues until recording is deliberately stopped.
**A backup capacitor maintains the date and time for more than 10 seconds to allow completely transparent
replacement of the batteries. Beyond 10 seconds, the date and time information must be reset (the
configuration and data are not affected). If the device remains linked to DataView
the battery life will be 100 hours whatever the recording rate chosen.
*** Input levels exceeding this limit may damage the device.
Captive MiniFlex
0.5 to 100 A
AC
0 to 1 A unspecified
1 to 100 A:
±(1% of Reading + 0.5 A)
Programmable from 125 ms to 1 day
Start/Stop, FIFO and Extended Recording Mode* (XRM™)
15 minutes to 8 weeks, programmable using DataView
240,000 measurements (512 KB).
Recorded data is stored in non-volatile memory and retained
even if battery is low or removed.
USB 2.0 optically isolated
2 x 1.5 V AA-cell alkaline batteries
100 hours to > 45 days (dependent on storage rate/recording length)
4.95 x 2.75 x 1.28" (136 x 70 x 32 mm) w/o Sensor
Sensor: 6" (152 mm) / Cable: 6 ft (2 m)
IEC 68-2-6 (1.5 mm, 10 to 55 Hz)
IEC 68-2-27 (30 G)
IEC 68-2-32 (1 m)
14° to 122°F (-10° to 50°C)
-4° to 140°F (-20° to 60°C)
Up to 85% at 95°F (35°C), Non-condensing
EN 61010-1; 600 V CAT IV; Pollution Degree 2
ML912
Two
®
AC Current Flexible Sensors
5 to 1,000 A
0 to 5 A unspecified
5 to 1,000 A:
±(1% of Reading + 1 A)
0.1 A
64 samples/cycle
8.67 oz (245 g)
UL94-V0
2000 m
IP40
EN 61326-1
Yes
TM
mode, every other item
®
via a desktop computer,
English
AC
®
Page 54