Keypad (HMI) and Basic Programming

4 KEYPAD (HMI) AND BASIC PROGRAMMING

4.1 INTEGRAL KEYPAD - HMI-CFW700

The integral keypad can be used to operate and program (view / edit all parameters) of the
CFW700 inverter. There are two operation modes in the keypad: monitoring and programming.
The key functions and display indications of the keypad may change according to the operation
mode. The programming mode consists of three levels.
- When in monitoring mode: press this
key to increase the speed.
- When in programming mode, level 1:
press this key to go back to the
previous group.
- When in programming mode, level 2:
press this key to go to the next
parameter.
- When in programming mode, level 3:
press this key to increase the
parameter value.
- When in programming mode, level
1: press this key to go back to the
monitoring mode.
- When in programming mode, level 2:
press this key to go back to the level 1.
- When in programming mode, level 3:
press this key to cancel the new value
(the value will not be saved) and it will
return to level 2 of the programming
mode.
- Press this key to define the motor
rotation.
This option is active when:
P0223 = 2 or 3 in LOC and/or
P0226 = 2 or 3 in REM.
- Press this key to change between
LOCAL and REMOTE mode.
This option is active when:
P0220 = 2 or 3.
- Press this key to accelerate the motor up to the speed set in P0122. The motor speed is maintained
while the key is pressed. When the key is released the motor decelerates up to its complete stop.
This function is active when all the following conditions are met:
1. Start/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
(1) Available from the serial number 1024003697.
26 | CFW700
- USB
(1)
communication port
Figure 4.1: Operator keys
- When in monitoring mode: press this key
to decrease the speed.
- When in programming mode, level 1:
press this key to go to the next group.
- When in programming mode, level 2:
press this key to go back to the previous
parameter.
- When in programming mode, level 3:
press this key to decrease the parameter
value.
- When in monitoring mode: press this
key to enter in the programming mode.
- When in programming mode, level 1:
press this key to select the desired
parameter group - it shows the
parameters of the selected group.
- When in programming mode, level 2:
press this key to show the parameter
- it shows the parameter value for its
modification.
- When in programming mode, level 3:
press this key to save the new parameter
value - it returns to level 2 of the
programming mode.
- Press this key to accelerate the motor
according to the acceleration ramp time.
This option is active when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
- Press this key to decelerate the motor
according to the deceleration ramp time.
This option is active when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.