5.2.2 Basic Application Menu
Step
Action/Display Indication
1
Monitoring mode.
Press the ENTER/MENU key to get into
the first level of the programming mode.
3
Press ENTER/MENU when the group is
selected.
5
I f n e c e s s a r y, c h a n g e " P 0 10 1 -
Deceleration Time".
Press the
parameter.
7
If necessary, change "P0134 - Maximum
Speed" parameter.
Press the
parameter.
9
If necessary, change "P0136 - Manual
Torque Boost" parameter.
Press the
parameter.
or
key to the next
or
key to the next
or
key to the next
Figure 5.2: Basic application group
Troubleshooting and Maintenance
Step
Action/Display Indication
2
The PARAM group is selected, press
the
or
group.
4
In this moment the Basic Application
routine is initiated. If necessary, change
"P0100 - Acceleration Time" parameter.
Press the
parameter.
6
If necessary, change "P0133 - Minimum
Speed" parameter.
Press the
parameter.
8
If necessary, change "P0135 - Max.
Output Current" parameter.
Press the
parameter.
10
Press the BACK/ESC key to end the Basic
Application routine.
Press the BACK/ESC again to go back to
the monitoring mode.
keys to select the BASIC
or
key to the next
or
key to the next
or
key to the next
CFW700 | 53